64
Custom Data String Control Characters
\a
Accumulated Weight (polarity = <sp>), 8 digits with leading spaces, and decimal
point)
\A
Accumulated Weight (polarity = "0"), 8 digits with leading zeros, and decimal
point)
\b
Dumps print buffer memory, clears buffer
\B
Clears Accumulator & Counter
\c
Accumulation Counter (7 digits, leading spaces)
\C
Accumulation Counter (7 digits, leading zeros)
\d
Current Weight (no polarity, no decimal point, 6 digits with leading zeros)
\D0
Current Product Description (20 characters thru serial port)
\DF
Current Product Description (fixed 20 characters including leading spaces)
\E0
Current Preact Weight (polarity (<sp> or “-”), 6 digits, and decimal point)
\Ex
Preact Weight (x = 1-8, Preact field location)(polarity (<sp> or “-”), 6 digits, and
decimal point)
\e
Check sum value
\fVx Data field, variable length up to 64 characters, x = 1-8 field number
\fFx
Data field, fixed 20 characters including leading spaces, x = 1-8 field number
\q
Current Gross weight (polarity (<sp> or “-”), 6 digits, and decimal point)
\n
Current Net weight (polarity (<sp> or “-”), 6 digits, and decimal point)
\p
Gross Weight in pounds (polarity (<sp> or “-”), 6 digits, and decimal point)
\k
Gross Weight in kilograms (polarity (<sp> or “-”), 6 digits, and decimal point
\g
Gross Weight in grams (polarity (<sp> or “-”), 6 digits, and decimal point)
\o
Gross Weight in ounces (polarity (<sp> or “-”), 6 digits, and decimal point)
\z
Gross Weight in lb-oz (polarity (<sp> or “-”), 6 digits, and decimal point)
\P
Net Weight in pounds (polarity (<sp> or “-”), 6 digits, and decimal point)
\K
Net Weight in kilograms (polarity (<sp> or “-”), 6 digits, and decimal point)
\G
Net Weight in grams (polarity (<sp> or “-”), 6 digits, and decimal point)
\O
Net Weight in ounces (polarity (<sp> or “-”), 6 digits, and decimal point)
\L
Net Weight in lb-oz (polarity (<sp> or “-”), 6 digits, and decimal point)
\m
Motion Status – shown in continuous print only ("MOT" or <SP><SP><SP> )
\hxx Hex command two digits (xx = hex #)
\H
Current Batch number (6 digits with leading zeros, 2200B multi-batch mode)
\i
Serial Scale Address (00-99)
\
I
0
Current Product ID (6 digits front panel or 20 characters thru serial port)
(2200/2200B/2200CW, one product)
\
I
0
Current Product ID (6 numeric digits) (2200CW, 250 products)
\
I
x
Product ID (x = 1-8, ID field location)(6 digits front panel or 20 characters thru
serial port or barcode entry) (2200/2200B/2200CW, one product)
\
I
F0
Current Product ID (fixed 20 characters including leading spaces)
\
I
Fx
Product ID (x = 1-8, ID field location)(fixed 20 characters including leading
spaces)(2200/2200B/2200CW, one product)
\s
Highest active setpoint number ("0", "1", "2", "3", "4", "5", "6", "7", or "8")
Check weight status (2200CW) ("HIGH ", "OVER '', "ACCEPT", "UNDER ", "LOW
", and " ")
\S0
Current Setpoint Weight (polarity (<sp> or “-”), 6 digits, and decimal point)
Summary of Contents for 2200 Series
Page 2: ...1 ...
Page 11: ...10 Scale Operation Fig 1 Model 2200 Front Panel Layout Fig 2 Model 2200B Front Panel Layout ...
Page 118: ...117 ...
Page 127: ...126 Fig 37 Mounting Dimensions ...
Page 136: ...135 ...