36
Calibration and Audit Counters
When entering calibration mode, the parameter audit counter and the calibration audit
counter will momentarily be displayed. The parameter audit counter only increments
when
CAP
,
Cnt by
,
A2t
,
nn.A.
,
SU0
,
oP
values are changed. The calibration audit
counter increments when a successful zero calibration and span calibration are
performed.
Note:
when the scale is in Legal For Trade Switch mode (
oP
=
44S
), the audit counters
will not be displayed.
Resetting the scale parameters:
If at some point the 2200 Series user wishes to return all parameters to factory default
settings, follow these steps.
Enter the Setup mode and press the UNITS button to scroll to menu item
"
dEFt n
".
Press the ZERO button to select "
dEFt y
". Press the UNITS button and the
display will show "
dEF2 n
".
Press the ZERO button to select "
dEF2 y
" to default all parameter and
calibration settings, except for zero & span calibration levels. OR
Press the ZERO button twice to select "
dEF2 C
" to default all parameter and
calibration settings, including zero & span calibration levels.
WARNING: Using "
dEF2 C
" selection to default the scale will require a complete
recalibration.
Press the UNITS button to default the scale.
The scale will then display "
InIt
" or "
InIt C
" and "
SAVEd
". After the "
SAVEd
"
message is displayed the scale will then perform its normal power up routine
and enter the Setup mode. All parameters have been reset to their factory
default settings.
If necessary, calibrate the indicator. Refer to the Calibration Mode Section for
calibration instruction, or exit the Setup mode to return to the weighing mode.
Note:
A second method to default parameter settings only is by holding the CAL push
button while powering up scale. The indicator will display "
rEL Pb
" until the CAL button
is released, then show "
InIt
" and "
SAVEd
".
Summary of Contents for 2200 Series