72
ET
* (acknowledgment, port 1 only)
Display will show "
SAVEd
" to indicate that the
Tare value has been successfully saved to
non-volatile memory.
Enter Tare weight value.
See Remote Tare Entry and Recall.
A
Accumulate stable weight value. Display will
show "
o
" to indicate that the Accumulation has
occurred.
Adds current stable weight value to
Accumulator, Counter is incremented.
RA
Accumulator weight value.
Read Accumulator weight value.
RC
Counter value.
Read Counter value.
CA
* (acknowledgment, port 1 only)
Display will show "
CLr Ac
" to indicate that the
Accumulator & Counter values have been
cleared
Clears Accumulator & Counter values.
BS
(2200B only)
* (acknowledgment, port 1 only)
Display will show "
StArt
" to indicate that the
Batch program has started.
When in the Batch mode, Scale will
run the batch program.
BX
(2200B only)
* (acknowledgment, port 1 only)
Display will show "
StOP
" to indicate that the
Batch program has stopped.
When in the Batch mode, Scale will
stop the batch program and jump to
line 1. All batch relay outputs inactive.
BP
(2200B only)
* (acknowledgment, port 1 only)
Display will show "
PAUSE
" to indicate that the
Batch program has paused.
When in the Batch mode, Scale will
pause at current step in the batch
program. All batch relay outputs
inactive.
ROx
Read Output Terminal (TB4) Status,
Respond with
ASCII (30h) 0 = non-active or
ASCII (31h) 1 = active
Reads status of Output number x = 1
to 8.
EOxy
* (acknowledgment, port 1 only)
Successfully saved to Output Terminal (TB4).
Enter value for Output number x = 1 to
8. Non-active y = 0 ASCII (30h) or
Active y = 1 ASCII (31h).
RB
Will respond with stored bluetooth module’s
address.
Request the 12 digit stored bluetooth
address (ASCII, leading zeros).
Efx
Enter Data Field,
* (acknowledgment, port 1 only)
Enter characters in Data Field number
x = 1 to 8. Maximum of 63 characters
can be enterd. See Data Field Entry
and Recall.
Rfx
Read Data Field,
* (acknowledgment, port 1 only)
Reads characters in Data Field
number x = 1 to 8. See Data Field
Entry and Recall.
RU
Read User ID.
Reads current User ID value.
EU
Enters User ID for login.
* (acknowledgment of login, port 1 only)
! (login does not match stored IDs, port 1 only)
Enters User ID value for login. Value is
compared with existing User ID values
stored in memory. See QC Weigh
software section.
Table 2: Doran serial protocol