22
To enter and save values for all fields associated with the current Product ID, simply
enter the values for each field.
NOTE: If the password protection is active, no new Product IDs can be entered. The
display will indicate this by momentarily showing a
PASS
message, followed by the
password entry mode.
Recall Existing Product ID (2200CW, 250 product setting)
Press PROD ID to enter the Product ID recall mode. The display will show
Id
, followed
by the currently active Product ID number. To select another stored ID number, enter the
preexisting ID number, then press ENTER. The display will read
SaVed
to indicate the
Check Limits, Tare weight, Product Description String, Accumulator and Counter fields
associated with that Product ID number are active.
Another method to select a different Product ID is to press PROD ID, then use the
UNITS or PRINT buttons to scroll through the available Product ID numbers. Press
ENTER to select the displayed Product ID. The display will read
SaVed
to indicate the
Check Limits, Tare weight, Product Description String, Accumulator and Counter fields
associated with that Product ID number are active.
Delete Product ID (2200CW, 250 product setting)
You may wish to remove Product IDs from your 2200CW to prevent accidental use.
Deleting a Product ID will make scrolling through the available Product IDs, using UNITS
or PRINT, a faster process.
Type in the Product ID number to be deleted. Momentarily press PROD ID to recall the
Product ID number. The display will show
pRd Id
, followed by the Product ID number.
Press and hold the CLEAR button for more than 2 seconds. The display will show
Clr
ID
and then
done
. All fields associated with that Product ID number will be cleared. The
previously used Product ID number will become active.
NOTE: If the password protection is active, Product IDs cannot be deleted. The display
will indicate this by momentarily showing a
PASS
message, followed by the password
entry mode.
Product ID Field Password Protection (2200CW, 250 product setting)
With password protection enabled, the user will be able to recall Product IDs, but not
alter any of the associated Product ID fields. The user will also be prohibited from
creating or deleting any Product IDs.
To disable password protection, enter the password and press ENTER. The display will
show
PASS
,
then
OFF
,
to indicate password protection is off.