13
2200CW
UNDER
ACCEPT
OVER
OVER
UNDER
PROD
ID
TARE
GROSS
UNITS
ENTER
CLEAR
ACCUM
SET
ZERO
[ ON/OFF ]
POINT
NET
Power Up and Power Down
Connect the indicator to a compatible power source and the indicator will turn on.
For scales with the battery option:
To turn on the scale, press and release the ZERO button.
To turn off manually, press and hold the ZERO push button until the display
shows "
rEL Pb.
" Then release the ZERO button and the scale will turn off.
The scale will turn off automatically when the scale is stable for a period of time
defined by the Unit On Timer parameter. The default setting is 30 seconds.
Software Part Number and Revision Level
During power up, the scale will display several messages. The first message is a
display test with all LED segments on (
888888
). Next, the scale will show the software
part number
Su 141
followed by the software revision level
rEv 1.0
or higher. When
contacting our service department, please have the software part number and the
revision level available.
ZERO Displayed Weight
To zero the scale, wait until the scale is stable and press the ZERO button. The scale
will not zero if the scale is in motion as indicated by the motion (MOT) annunciator.
Center of zero is indicated by the ZERO annunciator, which will be lit when the gross
weight is within 0.25 divisions of zero gross weight.