70
Command
(RXD)
Scale output Response (TXD)
Description
W or w
Will respond with current selected data string
transmitted from serial port 1. (No transmission
will occur if scale is in motion.)
Transmits data out TXD1 (Port1)
Wx or wx
Will respond with Custom Data String
transmitted from serial port 1.
Transmits Custom Data String number
x = 1 to 4 out TXD1 (Port1)
Transmits Data Output Format 1
x = 0 out TXD1 (Port1)
P or p
Will respond with current selected data string
transmitted from serial port 2. (No transmission
will occur if scale is in motion.)
If this command is sent from serial port 1, a “*”
will be sent out of port 1 to acknowledge the
command was executed.
Transmits data out TXD2 (Port2)
Px or px
Will respond with Custom Data String
transmitted from serial port 2.
If this command is sent from serial port 1, a “*”
will be sent out of port 1 to acknowledge the
command was executed.
Transmits Custom Data String number
x = 1 to 4 out TXD2 (Port2)
Transmits Data Output Format 2
x = 0 out TXD2 (Port2)
U or u
* (acknowledgment, port 1 only)
Scale changes current units
Z
* (acknowledgment, port 1 only)
Zeros scale
T or t
* (acknowledgment, port 1 only)
Tares Scale and enters Net mode
G or g
* (acknowledgment, port 1 only)
Scale enters Gross mode
N or n
* (acknowledgment, port 1 only)
Scale enters Net mode
d
Print Buffer data.
Display shows DUMP message while
transmitting.
Dumps serial data that is stored in
Print Buffer. Active when Serial
Handshaking is set for Buffer, 485 or
Bluetooth Buffer mode.
D
Print Buffer data & clears buffer.
Display shows DUMP message while
transmitting.
Dumps & clear serial data that is
stored in Print Buffer. Active when
Serial Handshaking is set for Buffer,
485 or Bluetooth Buffer mode.
CB
Clears Buffer data.
Clear serial data that is stored in Print
Buffer. Active when Serial
Handshaking is set for Buffer, 485 or
Bluetooth Buffer mode.
ELx
* (acknowledgment, port 1 only)
Enter data into Custom Data String
number x = 1 to 4
See Custom Data String Configuration
RLx
Label buffer string
Read data in Custom Data String
number x = 1 to 4
See Custom Data String Configuration
RSx
Setpoint or Check limit weight value.
Read weight value in Setpoint number
x = 1 to 8, 0 = current Setpoint number
Summary of Contents for 2200 Series
Page 2: ...1 ...
Page 11: ...10 Scale Operation Fig 1 Model 2200 Front Panel Layout Fig 2 Model 2200B Front Panel Layout ...
Page 118: ...117 ...
Page 127: ...126 Fig 37 Mounting Dimensions ...
Page 136: ...135 ...