109
TABLE VIII: DB150 Option Switches
Option
Switch #
Effect on System operation when "closed"
Def
OpSw 02
Booster only override
t
OpSw 03
DB150's booster is auto reversing
t
OpSw 05
DB150 is Command Station –Do Not Change
c
OpSw 13
Purge time increased to 600 seconds
t
OpSw 14
Purging is disabled
t
OpSw 15
Purging will force a loco to Stop or 0 speed
t
OpSw 17
Automatic advanced decoder assisted [FX] consists
are disabled
c
OPSw 18
Extend the DB150 booster short circuit shutdown
time from 1/8th to 1/2 second
t
OpSw 20
Disable address 00 or analog stretching for
conventional locomotives. "c" for German DB150 's.
t
OpSw 21
OpSw 21-23 set the global system default type for
"NEW" loco selections.
t
OpSw 22
SW21/22/23 set as follows
t-t-t=3 128 step mode
t-t-c= 7 128 step FX mode
t-c-t=1 Motorola Trinary
t
OpSw 23
c-t-t=2 14 step mode
c-c-t=0 28 step
t
OpSw 25
Do Not Change
c
OpSw 27
Disable normal switch commands, a.k.a. the
"Bushby bit." Allows attached PC to perform
switch control logic
t
OpSw 33
Allow track power to restore to prior state at power
on
c
OpSw 34
Allow track to power up to run state, if was run
prior to power own
c
OpSw 36*
Clear all mobile decoder information & consists
t
OpSw 38*
Clear the loco roster (aliasing with DT100)
t
OpSw 39*
Clear all internal memory states, including sections.
OpSw 36/37/38 cl ear
t
OpSw 41
Diagnostic click when valid LocoNet commands
incoming (useful for debug)
t
OpSw 42
Disable 3 beeps when Purgi ng occurs
t
OpSw 43
Disable LocoNet update of command station's track
status
t
OpSw 49
No beep when DB150 sends program command
t
OpSw 50
Longer booster short circuit recovery time
t
OpSw 51
Do not allow EXT voltage RESTART (with 2
nd
booster wired in parallel)
t