Troubleshooting
Troubleshooting
Digital PRIORIS HX MP Server
Digital PRIORIS HX MP Server
76
76
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
P
R
I
O
R
I
S
H
X
M
P
QAPlus/FE Error Messages
Component
Messages
Solution
CPU
Arithmetic Function Failed
General Functions Failed
Exception Interrupt in
Protected Mode
Refresh Failure
Logic Functions Failed
Reset CPU
Replace CPU
Hard disk
Butterfly Cylinder Access Test
Failed
Cylinder 0 Errors
Random Cylinder Access
Failed
Linear Cylinder Access Failed
Low-level format hard disk
Replace disk
Hard drive /
controller
Controller Diagnostic Test
Failed
Questionable Controller Card
Hard drives failed
Run Setup, Check connections
Reset controller, Replace controller
Replace disk
Floppy
diskette
Media Mismatch
Drive Not Ready
Write Protected Media
Unformatted Media
Use known good diskette
Check size and density of diskette
Close drive door
Remove write protection
Format diskette
Floppy drive
Floppy Drives Failed
Check connections, Replace drive
Battery/clock
Clock Stopped
Invalid Date
RTC Interrupt Failed
Run Setup
Replace battery/clock
CMOS
CMOS Clock Test Failed
Change time from Setup menu in QAPLUS
Serial port
COM port failed
Serial Chip Error
Serial Compare Error
Serial Timeout Error
Check COM device
Check connections
Replace COM device
Replace COM device
Video adapter
Video Failed
Error in Video Buffer
Replace video adapter
Replace video adapter