Service Procedures
Service Procedures
Digital PRIORIS HX MP Server
Digital PRIORIS HX MP Server
64
64
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
P
R
I
O
R
I
S
H
X
M
P
3-Channel RAID Configuration (All Internal Channels)
To connect SCSI devices to a 3-channel RAID host adapter, perform the following:
1) Connect the SCSI cables as shown in Figure 3 - 26. If necessary, connect appropriate power cable to
device.
2) Replace and lock side panels.
3) Connect external devices and restore power.
4) Run SCU and RAID configuration utility to configure the server.
Refer to the RAID documentation
for additional configuration information.
Legend
Component
A
RAID host adapter (channel C, host termination)
B
RAID host adapter (channel B, host termination)
C
Backplane, 68-pin connector
D
Terminator
E
68-pin-to-50-pin adapter cable to top-right drive bay
F
68-pin-to-50-pin adapter cable to CD-ROM drive
G
RAID host adapter (channel A, host termination)
H
Cable terminator
Figure 3 - 26 3-Channel RAID
Bus (All Internal Channels)
DEC00574
A
B
D
D
C
H
E
F
C
G