POST and Boot Messages
The POST displays messages to alert to errors in hardware, software, and firmware or to provide operating
information about the server.
Each time the POST displays a message on the screen, the server's speaker beeps twice. If an error occurs
before the monitor is initialised, specific beep codes sound to alert to a problem. The following table lists a
general grouping of system messages. In addition, each message is accompanied by text describing the
message and in most cases, a recommended solution to the problem.
NOTE
Italics indicate variable parts of a message such as memory addresses, hexadecimal
values, and so on. These messages can differ at each occurrence.
Message
Description/Solution
nnnn
Cache SRAM Passed
Where
nnnn
is the amount of server cache (in kilobytes) that tested
successfully.
Diskette drive A error
Diskette drive B error
Run the SCU. Check all connections.
Entering SETUP
BIOS Setup utility runs.
Extended RAM Failed at
offset:
nnnn
Extended memory failed or configured incorrectly.
Make sure SIMMs are installed correctly If the problem persists,
replace SIMMs.
Run the SCU and restore all settings to original values.
Extended RAM Passed
Where
nnnn
is the amount of extended memory (in kilobytes) that
tested successfully.
Failing Bits:
nnnn
nnnn
is a map of the bits at the RAM address that failed the memory
test.
Run the SCU and restore all settings to original values.
Fixed Disk 0 Failure
Fixed Disk 1 Failure
Fixed Disk Controller failure
Run the SCU. Check all connections.
Incorrect Drive A type - run
SETUP
Incorrect Drive B type - run
SETUP
Diskette drive A and/or B not correctly identified in the SCU.
Run the SCU and properly identify diskette drive A and/or B.
Invalid NVRAM media type
NVRAM access failed.
Run the SCU and restore all settings to original values.
Keyboard controller error
Keyboard error
Keyboard locked -
Unlock key switch
Check the keyboard connection. If the connection is secure, the
keyboard or keyboard controller might have failed.
Monitor type does not match
CMOS -
Run SETUP
Run the SCU and set the correct monitor type.
Operating system not found
The operating system cannot be found on drive A or drive C.
Run the SCU and correctly identify drive A or drive C.
Correctly install the operating system. Refer to the supplied
operating system documentation.