Service Procedures
Service Procedures
Digital PRIORIS HX MP Server
Digital PRIORIS HX MP Server
60
60
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
P
R
I
O
R
I
S
H
X
M
P
Single Channel SCSI and RAID Configuration
To connect SCSI devices to a single channel SCSI and RAID host adapter, perform the following:
1) Connect the cables as shown in Figure 3 - 22. If necessary, connect appropriate power cable to
device.
2) Replace and lock side panels.
3) Connect external devices and restore power.
4) Run SCU and the SCSI configuration utility to configure the server
. Refer to the SCSI and RAID
documentation for additional configuration information.
NOTE
Server’s with this configuration are shipped with an additional terminator and a two
connector cable to enable you to split the storage backplane.
Legend
Component
A
SCSI host adapter (SCSI bus, host termination)
B
RAID host adapter (channel A, host termination)
C
External SCSI connector
D
Backplane terminator
E
Jumper cable
F
Backplane, 68-pin connector
G
Cable terminator
H
68-pin-to-50-pin adapter cable to top-right drive bay
I
68-pin-to-50-pin adapter cable to CD-ROM drive
Figure 3 - 22 Single Channel SCSI and
RAID Bus
DEC00576
A
B
C
D
E
F
G
H
I
C