Digital PRIORIS HX MP Server
Digital PRIORIS HX MP Server
Service Procedures
Service Procedures
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
53
53
P
R
I
O
R
I
S
H
X
M
P
Removing and Replacing the Terminator Card
The terminator card terminates the memory and CPU bus for the PRIORIS HX MP one and two processor
(1P, 2P) configurations. When upgrading to the four processor (4P) configuration, replace the terminator
card with a second CPU module.
To remove the terminator card:
1) Turn off the server.
2) Disconnect external devices, ac power, and monitor power.
3) Unlock and remove left side panel.
4) Remove terminator card.
5) Install CPU module and secure with retaining bracket.
6) Replace and lock left side panel.
7) Connect external devices and restore power.
NOTE
The server will not power up with the side panel removed.
DEC00579-4
Figure 3 - 17 Removing a Terminator Card