Service Procedures
Service Procedures
Digital PRIORIS HX MP Server
Digital PRIORIS HX MP Server
54
54
MCS Logistics Engineering - Nijmegen
MCS Logistics Engineering - Nijmegen
P
R
I
O
R
I
S
H
X
M
P
Removing and Replacing a Memory Module
The PRIORIS HX MP server comes with a single memory module that supports a 128-bit memory
interface and 2-way memory interleaving. The server’s overall performance can be increased by adding an
additional memory module.
NOTE
Due to height limitations, 64 MB SIMMs cannot be used on the PRIORIS HX MP
memory modules.
The following procedure can be used to remove and replace any memory module:
1) Turn off the server.
2) Disconnect external devices, ac power, and monitor power.
3) Unlock and remove left side panel.
4) Remove memory module retaining bracket.
5) Carefully remove memory module from main logic board.
6) Install an additional memory module or add additional server memory on existing memory module.
7) Replace memory module and secure with retaining bracket.
8) Replace and lock left side panel.
NOTE
The server will not power up with the side panel removed.
9) Connect external devices and restore power.
10) Run the SCU, select
Configure Computer
, select
View and Edit
Details
, and then select
Save and Exit
.
Figure 3 - 18 Removing
the Memory Module
DEC00579-3