Installation Procedures
2.1 Preparing the Site
Table 2–2 BA42B Electrical Requirements
Parameter
Values
Nominal voltages
110 V ac or 220 V ac
Voltage ranges
100 V ac to 120 V ac (88 V rms
1
to 132 V rms) and
220 V ac to 240 V ac (176 V rms to 264 V rms)
Power source phase
Single
Nominal frequencies
50 Hz
2
or 60 Hz
Frequency range
47 Hz to 63 Hz
Maximum running current
1.2 A for 110 V ac systems and 0.6 A for 220 V ac
systems
Steady state current
1.0 A for 110 V ac systems and 0.5 A for 220 V ac
systems
Maximum inrush current
32 A
Maximum power consumption
120 W
1
Root mean square (rms).
2
Hertz (Hz).
2.2 Unpacking the System
Open the container. Remove the box and the accessory tray. The box contains
the system unit. The accessory tray contains the following:
•
Customer Hardware Information Kit
•
OpenVMS Factory Installed Software User Guide
• Software licenses
• Power cord
• Other accessories
Expansion boxes, if ordered, are supplied in separate containers.
Depending on the system configuration, the contents of the container may
differ from the items shown in Figure 2–2. When unpacking the system, do the
following:
1. Check the contents of the container against the packing slip.
2. Store the unused parts for future use. Depending on how you set up the
system, you may not use all the components supplied with the system.
Installation Procedures 2–5