Removing and Replacing Field Replaceable Units
3.2 Removing an MS44 or MS44L Memory Module
3.2 Removing an MS44 or MS44L Memory Module
To remove a memory module:
1. Remove the ac power from the BA42B Enclosure.
2. Remove the enclosure cover (refer to Section 3.1).
Caution
Static electricity can damage integrated circuits. Wear a wrist strap
and place an antistatic mat under the system unit when working with
the internal parts of the system unit.
3. Locate the faulty memory module. Figure 3–3 shows the location of the
memory module connectors on the KA52/KA53 CPU module.
Note
• Note the position of the faulty memory module on the CPU
module. You must install the replacement in the same position.
See Section 1.5.1 for memory configurations.
• You may have to remove one or two memory modules to reach
the faulty memory module. Note carefully the position of each
memory module you remove.
3–6 Removing and Replacing Field Replaceable Units