20-32
4.2
OVERALL PROGRAMMING
ATTENTION!
•
Complete programming (i.e. access to all parameters) is only possible on level III.
Saving data contained in the ECU:
•
With "ECU -> file" read data from ECU. The "Save file under" window is shown.
•
Save data under any name as Hex-File (file name.hex).
Complete programming of ECU:
•
Click on key "Programming" and the "Open" window is shown.
•
Select desired Hex file and open.
•
" Click on key "Save in ECU".
Of the configuration data only that operating data is shown which was read from the ECU (2nd column) or from a file (3rd
column. Prior to uploading of the configuration data to the ECU, the operating data can be edited in the 4th column. This
data is also uploaded when uploading the configuration data to the ECU.
Figure: Menu complete programming (“Overal programming”)
EXPLANATION OF FUNCTION[ SWITCH:
ECU->fi!e
: The configuration data is read from the ECU, displayed and can be saved as HEX file.
Programming:
Updated configuration data is uploaded to the ECU, In order for the upload to be permanent, you must op-
erate the "Save in ECU" switch on the ECU.
Save in ECU (only applies for EMR):
The configuration data are permanently saved in the ECU
Restriction:
Only applies for EMR and EMS.
4.3
CALIBRATION
The accelerator pedal and the hand throttle potentiometer (if any) must be calibra-ted in combination with the EMR (not ap-
plicable for gensets).
Important prerequisites:
•
Engine shut off
•
Supply voltage (ignition/terminal 15) switched on
•
Accelerator in frame
SERDIA
PARAMETERS
Summary of Contents for AGROTRON 106 MK3
Page 2: ......
Page 4: ......
Page 18: ......
Page 46: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 71: ...10 53 4 FRONT AXLE D0004780 1710 1710 B B A A 0 52º 2 FRONT AXLE ...
Page 102: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 116: ......
Page 119: ...20 1 OPERATOR S MANUAL SERDIA LEVEL III SERDIA OPERATOR S MANUAL ...