20-20
SERDIA negates CanRxObjActive in bits (inactive message) and then performs an AND combination with CanConf_bits in
bits. As result one obtains in bits the receipt messages which are configured and inactive (CanRxTimeOutBits).
A text is assigned to each bit of CanRxTimeOutBits, which represents the name of the relevant receipt messages. As not
all bits may be used, it is defined in the text by entering "dc" for "don't care" that the text output is suppressed for this bit.
If the text "100 Receipt message failed" is displayed, there is an additional text output of the list of missing receipt mes-
sages.
3.6
EXAMPLE OF A DISPLAYED ERROR INFORMATION:
100 Receipt message failed
Engine Temperature
Engine Fluid Level
Pressure Function shift
Inlet / Exhaust Conditions
VanRxTimeOutBit
Text
0
Engine Temperature
1
Inlet / Exhaust Conditions
2
Engine Fluid Level /Pressure
3
TSC1
4
Engine protection
5
Function shift
6
Dc
7
Dc
8
Dc
9
Dc
10
Dc
11
Dc
12
Dc
13
Dc
14
Dc
15
Dc