20-24
MK 3
TTG
Parameter
Unit
Min.
Max.
typ
Wert
Description
Page 7: Monitoring
CoolTempMon.:
ShutoffValue
°C
-30
130
118
Limit engine shutoff (130° = none)
CoolTempMon.:
Shutoff Delay
s
0
600
0
Time delay engine shutoff
CoolTempMon.:
RecovValue
°C
-30
130
110,0
Reset limit
CoolTempMon.: Fuel qty red.
%
0
100
20
Fuel inj. quantity reduction (0% = none)
CoolTempMon.: Red. delay
s
0
600
15
Time delay fuel inj.quantity reduction
CoolTempMon.: Alarm limit
°C
-30
130
113
Limit alarm
OilPrMonitor: shutoff fact
%
0
100
80
Factor for limit engine shutoff (0% = none)
OilPrMonitor:
shutoff delay
%
0
100
20
Time delay engine shutoff
OilPrMonitor:
recov fact
%
0
100
20
Factor for reset value
OilPrMon.:
Power Red. delay
s
0
600
15
Time delay fuel inj. quantity reduction
Engine speed position
valuesp
1/min
500...260
0
8 Engine speed values
Oil pressure warning
bar
0...0,5
Oil pressure warning limit=fct(speed)
Page 9: Sensor calibration values
The following values are dependent only on the type of sensor used and consequently do not generally need to be changed.
BPSensor: upper err limit
digits
0
1023
820
Boost pr. sensor: upper failure trigger point
BPSensor: upper ref (2 bar)
digits
0
1023
454
Boost pr. sensor: voltage at 2 bar
BPSensor: lower ref (1 bar)
digits
0
1023
219
Boost pr. sensor: voltage at 1 bar
BPSensor: lower err limit
digits
0
1023
60
Boost.pr. sensor: lower failure trigger point
OilPrSens.:upper err limit
digits
1023
820
Oil pr. sensor: upper failure trigger point
OilPrSens.:upper ref (5 bar)
digits
0
1023
511
Oil pr. sensor: voltage at 5 bar
OilPrSens.:lower ref (0 bar)
digits
0
1023
102
Oil pr. sensor: voltage at 0 bar
OilPrSens.:lower err limit
digits
0
1023
40
Oil pr. sensor: lower failure trigger point
CoolTempSens.:up. err limit
digits
0
1023
1020
Coolant temp. sensor: upper failure trigger point
CoolTempSens.:lo. err limit
digits
0
1023
10
Coolant temp. sensor: lower failure trigger point
LowerMapBranch
TempSensor
digits
0
26...394
4 values
UpperMapBranch
TempSensor.
digits
64...838
6 values
Page 10: Setpoint gen. calibration values
T1:setpoint sensor
0
255
2
Smoothing time constant SWG
The following 8 parameters can be set with the menu ”Calibration”, see 4.3. - *SWG = setpoint sensor
AccPedal(SWG1)up. err val.
digits
0
65535
963
SWG1: upper failure trigger point
AccPedal(SWG1)up. ref.
digits
0
65535
922
SWG1: voltage max. position
AccPedal(SWG1)lo. ref.
digits
0
65535
103
SWG1: voltage min. position
AccPedal(SWG1)lo. err val.
digits
0
65535
62
SWG1: lower failure trigger point
Hand thr. (SWG2)up. err val.
digits
0
65535
961
SWG2: upper failure trigger point
Hand thr. (SWG2)up. ref.
digits
0
65535
830
SWG2: voltage max. position
Hand thr. (SWG2)lo. ref.
digits
0
65535
190
SWG2: voltage min. position
Hand thr. (SWG2)lo. err val.
digits
0
65535
61
SWG2: lower failure trigger point
SERDIA
PARAMETERS
Summary of Contents for AGROTRON 106 MK3
Page 2: ......
Page 4: ......
Page 18: ......
Page 46: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 71: ...10 53 4 FRONT AXLE D0004780 1710 1710 B B A A 0 52º 2 FRONT AXLE ...
Page 102: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 116: ......
Page 119: ...20 1 OPERATOR S MANUAL SERDIA LEVEL III SERDIA OPERATOR S MANUAL ...