10-96
2.
When the lift is raised
•
When the lift is raised, the electronic lift control energises the solenoid (4) which move the spool (5) to the right.
•
The oil in passage
b
can therefore flow through the check valve (2) into chamber
e
and from there to the lift cylinders.
•
At the same time, the pressure present in passage
b
can flow into the chamber
i
and into the passage
f
and from there
through the channel
g
into chamber
h
of the flow control (1).
•
As the oil pressure is the same on both sides of the spool, the spool is shifted by the force of the spring (6) and the oil
can flow from chamber
a
into the passage
b
.
D0004940
1
e
g
b
f
2
5
4
6
a
h
i
R
A
P
HYDRAULIC SYSTEM