Description varix 200/varix 14 (DECT)
1 - 17
1 Description
Digital UP0/UPD
subscriber line interface
- Number of wires
two
- Net bit rate
144 kbit/s
- Bit clock rate
384 kbit/s
- Burst frame period
250 µs
- Burst period
99 µs
- Frame length
38 bit
- Termination resistance
100 Ohms
- Transmission code
AMI, half-bauded
Connection specifications for door release / intercom
- Output impedance / signal levels correspond to a/b interface
- Amplifier disconnection is not implemented
Door release relay
The ring signal relay of the respective A/B subscriber line is used; specifications:
- Switching voltage
< 100V
- Switching current
< 2 A
- Switching load
< 50 W
The relay contact is protected by a spark suppression circuit.
DECT in general
Carrier frequencies:
10 carrier frequencies, starting with 1881.792 MHz and at
intervals of 1.728 MHz are used (highest frequency 1897.344
MHz).
Time slots:
Each of the 10 carrier frequencies has 24 time slots (12 in trans-
mission direction and 12 in the receiving direction), transmission
and reception time slots are separated in time. This results in a
total of 120 time-slot pairs for full duplex operation. For technical
reasons, only every second time slot is used in the DeTeWe-speci-
fic implementation. This means that the total capacity is reduced
to 60 time-slot pairs in this case.