Testing
There are various functions that allow you to test that your system is operating correctly.
Horn Speaker Test
1.
Hold down button 1 until two beeps are heard.
The horn speaker will sound for two seconds.
Bell Test
1.
Hold down button 2 until two beeps are heard.
The bell output will operate for two seconds.
Strobe Test
1.
Hold down button 3 until three beeps are heard.
The strobe will now flash.
2.
Hold down button 3 until two beeps are heard.
The strobe will now stop flashing.
Walk Test Mode
Walk test mode allows you to test detection devices to ensure that they are operating
correctly. Every time you test a zone, the Keypad will sound one long beep and the horn
speaker will sound one short beep to indicate that the zone has been activated when testing.
1.
Enter your Master Code followed by 7 and the # button (eg. 2580 +7#).
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
The Keypad will beep once every second while the system is in walk test mode.
2.
Activate all zones that are required to be tested.
3.
When you have finished testing all zones required, press the # button to exit this
mode. Two beeps will be heard and the STAY and AWAY indicators will extinguish.
The system has now returned to the Unset state.
Test Report
This feature is only applicable if your system is reporting via the telephone. Press and hold
button 9 until two beeps are heard. The system will send a test report.
Event Log
This function allows you to replay back the last forty events that occurred to the system. The
event Log will replay all alarms and setting/Unsetting of the system in AWAY Mode, STAY
Mode 1 and STAY Mode 2. However, the system cannot differentiate between setting the
system in STAY Mode 1 or STAY Mode 2.
How To Enter Event Log
1.
Enter your Master Code followed by 8 and the # button (eg. 2580 + 8#).
Three beeps will be heard. The last forty events will display one at a time via the
Keypad indicators starting from the most recent event. A beep will be heard as each
event is displayed.
24
Solution
Ultima Operators Manual
Operators Manual UK
Detection Systems