Reset Latching Outputs
This feature is only applicable if your Engineer has programmed an output to latch (remain
on) until you acknowledge the event that occurred.
How To Reset Latching Outputs
1.
Hold down button 7 until two beeps are heard.
The output will now reset.
Call Divert On/Off (System Set/Unset)
This feature allows you to program the Call Divert Set Sequence and Call Divert Unset
Sequence.
Call Divert Set Sequence
This allows you to program the Call Divert sequence that will automatically operate when
you Set the system in the AWAY Mode. This feature is only available if your
telecommunications provider has the call-Divert option available.
Call Divert
You can redirect calls to anywhere in UK, including mobiles, pagers and answering services.
When Call Divert is turned on, your telephone will not ring.
Note: The examples below are using the BT call divert codes. These codes may differ if
different telephone network is being used.
How To Program The Call Divert Set Sequence
1.
Enter your Master Code followed by 3 and the # button (eg. 2580 + 3#).
Three beeps will be heard and the STAY and AWAY indicators will flash.
2.
Press button 1 followed by the # to select the Call Divert Set sequence. Three beeps
will be heard.
3.
Enter the call divert sequence that you require (*21*Phone Number # PPPPP).
Remember that when you program a * in the Call Divert Set sequence, you enter
*1 when you program a # in the Call Divert Set sequence, you enter *2 and when
you program P (pause) in the Call Divert Set sequence, you enter *3.
4.
Press the # button when finished.
Two beeps will be heard and the STAY and AWAY indicators will extinguish.
Note: To disable the Call Divert Set Sequence, enter the Call Divert sequence as
*4 (break) for Step 3.
22
Solution
Ultima Operators Manual
Operators Manual UK
Detection Systems