Figure 3: CP5 LED Keypad
Showing Audible Alarm
Buttons
Keypad Duress Alarm
A Keypad duress alarm is used as a silent hold-up alarm. This will only occur when the
number 9 is added to the end of any valid user code that us being used to Unset the system
(eg. 2580 + 9#). A duress alarm is only useful if your system is reporting back to a
monitoring station or pocket pager as domestic reporting (i.e. mobile phone etc) can’t
decipher which type of alarm had occurred.
Keypad Panic Alarm
An audible alarm will be activated when both the 1 and 3 buttons or both the *
and # buttons are pressed simultaneously. Contact your Engineer if you wish to
disable the ability to activate the Keypad panic alarm or if you wish to have the
Keypad panic alarm to be silent.
Keypad Fire Alarm
A distinct fire sound is emitted via the horn speaker when both the 4 and 6
buttons on the Keypad are pressed simultaneously. Contact your Engineer if you
wish to disable the ability to activate the Keypad fire alarm or if you wish to
have the Keypad fire alarm to be silent.
Keypad Medical Alarm
An audible alarm will be activated when both the 7 and 9 buttons on the Keypad
are pressed simultaneously. Contact your Engineer if you wish to disable the
ability to activate the Keypad medical alarm or if you wish to have Keypad
medical alarm to be silent.
Keypad Tamper (Access Denied)
Keypad tamper restricts the number of times an invalid user code can be used in an attempt
to operate the system. When the number of incorrect code attempts equals the number
programmed by your Engineer, the system will activate an alarm condition and if reporting
back to a security monitoring station, the system will send an access denied report.
If you wish the Keypads to shutdown and lockout for a period of time (0 – 150 seconds), ask
your Engineer to program this.
16
Solution
Ultima Operators Manual
Operators Manual UK