Setting In STAY Mode 1
STAY Mode 1 is only used when the perimeter and unused areas of the premises need to be
Set to detect any would be intruder from entering the premises and at the same time,
allowing you to move freely within an area that has been automatically omitted. Only your
security company can program zones to be automatically omitted in STAY Mode 1.
There are two different methods for setting the system in STAY Mode 1. Method one is
standard and will always operate. Method two is optional and may be disabled by your
Engineer if you do not wish to use single button setting.
Entry Guard Timer For STAY Mode
When setting the system in STAY Mode 1, an optional entry timer called Entry Guard Timer
For STAY Mode may be used to delay the sirens if a zone that has not been automatically
omitted has triggered into alarm condition. Entry Guard Timer For STAY Mode is the delay
time used for all zones except 24-hour zones when the system is Set in STAY Mode 1 or
STAY Mode 2.
If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not
been automatically omitted has triggered, the Keypad will beep twice a second until the
Entry Guard Timer For STAY Mode has expired or the system has been Unset. If the alarm
condition has not been reset by entering your user code followed by the # button (eg. 2580#)
before the Entry Guard Time For STAY Mode expires, the sirens will activate into alarm.
Only your Engineer can program this feature.
Method One
How To Set The System In STAY Mode 1
1.
Enter your user code followed by the * button (eg. 2580*).
Two beeps will be heard and the STAY indicator will display. Exit time will now
commence counting.
Any zones that have been programmed to be automatically omitted in STAY Mode 1
will flash until exit time expires. At the end of exit time, all zones selected to be
automatically omitted will extinguish and the Keypad will give one short beep.
Method Two
How To Set The System In STAY Mode 1
1.
Hold down the * button until two beeps are heard.
The STAY indicator will display and exit time will now commence counting.
Any zones that have been programmed to be automatically omitted in STAY Mode 1
will flash until exit time expires. At the end of exit time, the zone indicators will
extinguish and the Keypad will give one short beep.