![Detection Systems solution ultima Operator'S Manual Download Page 20](http://html1.mh-extra.com/html/detection-systems/solution-ultima/solution-ultima_operators-manual_2487630020.webp)
RF Receiver Fail
The RF receiver fault will register once the system has detected that the wireless receiver
unit has been disconnected.
Horn Speaker
This fault will register when the system detects that the horn speaker has been disconnected.
This fault will clear once the horn speaker has been reconnected. Your Engineer will need to
program the system for this feature to operate.
Telephone Line Fail
A telephone line fault will register when the system detects that the telephone line has been
disconnected from the control panel. Your Engineer will need to program the system for this
feature to operate.
E2 Fault
An E2 fault will register when the system detects an internal checksum error. Contact your
Engineer as soon as this fault is displayed.
Fuse Fail
This fault will occur when either of the two 1 Amp fuses has blown. Contact your Engineer
as soon as this fault is displayed.
RF Low Battery
This fault will occur when any of the RF wireless devices has reported a low battery
condition to the control panel. Whilst you are in fault analysis mode, press and hold button 2
until two beeps are heard will display which zone has reported the RF Low Battery fault.
Tamper Fail
This fault will occur when any zone has become open circuit. By press and hold button 3
until two beeps are heard in fault analysis mode will display which zone has reported the
tamper fail fault.
Sensor Watch Fault
A sensor watch fault will register because one or more detection devices has failed to detect
any movement during the Unset state for the time period programmed by your Engineer.
The fault will clear once the zone in question has detected movement and reset.
Whilst you are in fault analysis mode, press and hold button 4 until two beeps are heard will
display which zone reported the sensor watch fault.
RF Sensor Watch Fault
An RF sensor watch fault will register because one or more RF detection devices has failed
to communicate to the RF radio receiver for the time period programmed by your Engineer.
The fault will clear once the RF device in question has successfully transmitted to the RF
radio receiver.
Whilst you are in fault analysis mode, press and hold button 5 until two beeps are heard will
display which RF detection device reported the RF sensor watch fault.
2
3
4
5
20
Solution
Ultima Operators Manual
Operators Manual UK
Detection Systems