![Detection Systems solution ultima Operator'S Manual Download Page 18](http://html1.mh-extra.com/html/detection-systems/solution-ultima/solution-ultima_operators-manual_2487630018.webp)
Code To Omit
The method of code to omit restricts only those user codes that have the priority level “Code
To Omit” set to be able to omit zones. Therefore, if any user code has this priority level set,
the method of standard omitting will not function.
How To Omit A Zone
1.
Press the * button followed by your user code and the * button again to enter the
omitting mode (eg. *2580*). Three beeps will be heard and the STAY indicator will
flash.
2.
Enter the zone number (1 – 8) that you wish to select to omit followed by the * button.
(eg. 1* = Zone 1, 2* = Zone 2 etc).
As you select each zone to be omitted, you will notice that the corresponding zone
indicator will begin to flash. If you selected an incorrect zone to be omitted, enter the
incorrect zone number again followed by the * button.
Repeat Step 2 if more than one zone is required to be omitted until all zones that are
required to be omitted have been selected.
3.
Press the # button after you have selected all zones to be omitted.
Two beeps will be heard and the system will return to the Unset state.
Fault Analysis Mode
If a system fault should occur, the FAULT or MAINS indicator will flash and the Keypad
will beep once ever minute.
If the AC mains supply has failed, the MAINS indicator will flash until the AC mains supply
has restored. Pressing the # button once will acknowledge the fault and stop the Keypad
from beeping once every minute.
How To Determine The Type Of System Fault
To determine which system fault has occurred, enter fault analysis mode by following the
steps outlined below.
1.
Hold down button 5 until two beeps are heard.
The FAULT indicator will remain steady and the STAY and AWAY indicators will
flash in unison with each other.
A zone indicator will display to indicate the type of fault that has occurred (eg. Zone 1
= System Fault). Refer to Table 7: Fault Indicators on page 18 for the list of different
faults that may occur.
2.
To further determine the type of fault condition (eg. System Fault), you will need to
press and hold down the button that corresponds to the zone indicator displayed (i.e. If
Zone 1 was displayed in Step 1, press and hold button 1 to display which system fault
has occurred).
3.
To exit and return to the Unset state, press the # button. The FAULT indicator will
remain displayed and the Keypad will cease its once a minute beep.
18
Solution
Ultima Operators Manual
Operators Manual UK
Detection Systems