Solution Ultima
Operators Manual
ISSUE 1.00
A member ofthe Bosch Group
Page 1: ...Solution Ultima Operators Manual ISSUE 1 00 A member of the Bosch Group...
Page 2: ...ent trademark names may have been used Rather than put a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to the benefit o...
Page 3: ...Y Mode 11 Setting In STAY Mode 1 12 Entry Guard Timer For STAY Mode 12 Setting In STAY Mode 2 13 Entry Guard Timer For STAY Mode 13 Programming STAY Mode 2 Zones 13 UNSETTING THE SYSTEM 14 ADDING USER...
Page 4: ...TCHING OUTPUTS 22 CALL DIVERT ON OFF SYSTEM SET UNSET 22 Call Divert Set Sequence 22 Call Divert Unset Sequence 23 TESTING 24 Horn Speaker Test 24 Bell Test 24 Strobe Test 24 Walk Test Mode 24 Test Re...
Page 5: ...ALLING 27 Acknowledging Domestic Calls 27 Programming Domestic Telephone Numbers 28 Disable Domestic Dialling 28 BASIC PAGER REPORTING 29 Basic Pager Display Information 29 Site ID Number 29 Zone Stat...
Page 6: ...r every possible requirement Programming simplicity and speed have been some of the major considerations and we believe that our objectives in this area have been more than satisfied This manual will...
Page 7: ...e seen Zone Indicators The zone indicators 1 8 are used to display the status of the zones The following table lists the various circumstances that the indicators will display i e Zone Closed Zone Ope...
Page 8: ...different methods of setting the system in AWAY Mode AWAY Indicator Definition On System Is Set In AWAY Mode Off System Is Not Set In AWAY Mode Table 2 AWAY Indicator 8 Solution Ultima Operators Manua...
Page 9: ...tus Day Alarm Turned On Table 3 STAY Indicator System Unset This indicator will display with the indicator when the system has been Unset MAINS Indicator The MAINS indicator is used to display that th...
Page 10: ...Acknowledged Table 5 FAULT Indicator Audible Indications In general the audible indicators given out by the Keypad buzzer are as follows Audible Indicator Definition Once Short Beep A Button Has Been...
Page 11: ...grammed to be automatically omitted by the Master Code holder Refer to Setting In STAY Mode 2 on page 12 Forced Setting The feature of setting the system when a zone is not Closed is known as forced s...
Page 12: ...ically omitted has triggered the Keypad will beep twice a second until the Entry Guard Timer For STAY Mode has expired or the system has been Unset If the alarm condition has not been reset by enterin...
Page 13: ...am this option How To Set The System In STAY Mode 2 1 Hold down the 0 button until two beeps are heard The STAY indicator will display and exit time will now commence counting Any zones that have been...
Page 14: ...nter the digits required for the new code followed by the button eg If you wish the user code to be 5768 you would enter 5768 Two beeps will be heard and the STAY and AWAY indicators will extinguish I...
Page 15: ...u wish to delete followed by the button eg 2 User 2 16 User 16 etc Two beeps will be heard and the user number that you just selected will now display on the Keypad indicators 3 Press the button to de...
Page 16: ...tons on the Keypad are pressed simultaneously Contact your Engineer if you wish to disable the ability to activate the Keypad fire alarm or if you wish to have the Keypad fire alarm to be silent Keypa...
Page 17: ...omit zones without the need to know a valid user code How To Omit A Zone 1 Press the button twice to enter the omitting mode Three beeps will be heard and the STAY indicator will flash 2 Enter the zo...
Page 18: ...FAULT or MAINS indicator will flash and the Keypad will beep once ever minute If the AC mains supply has failed the MAINS indicator will flash until the AC mains supply has restored Pressing the butt...
Page 19: ...tem fault will only display when any of the following faults occur After entering fault analysis mode press and hold button 1 will determine which of the following faults have occurred Low Battery A l...
Page 20: ...on 2 until two beeps are heard will display which zone has reported the RF Low Battery fault Tamper Fail This fault will occur when any zone has become open circuit By press and hold button 3 until tw...
Page 21: ...3 Press the button to exit and return to the Unset state Two beeps will be heard and the STAY and AWAY indicators will extinguish If a long beeps is heard an error was made when entering the date and...
Page 22: ...lephone will not ring Note The examples below are using the BT call divert codes These codes may differ if different telephone network is being used How To Program The Call Divert Set Sequence 1 Enter...
Page 23: ...nce that you require 21 PPP Remember that when you program a in the Call Divert Unset sequence you enter 2 and when you program P pause in the Call Divert Unset sequence you enter 3 4 Press the button...
Page 24: ...cond while the system is in walk test mode 2 Activate all zones that are required to be tested 3 When you have finished testing all zones required press the button to exit this mode Two beeps will be...
Page 25: ...he telephone For obvious security reasons the system cannot be Unset using this method To make use of this feature you will require a touch tone telephone Your Engineer needs to program this feature t...
Page 26: ...control panel Area Display Indicators The group of four AREA DISPLAY indicators show which area that the zones displayed belong to Status Indicators A group of four indicators display the following A...
Page 27: ...to three different telephone numbers may be programmed for the control panel to call when alarm occurs Only your Engineer can set the system to report in the domestic format however the Master Code ho...
Page 28: ...a break between the first telephone number and the second telephone number If there is only one telephone number to be programmed press the button to exit this function 4 Enter all the digits of the...
Page 29: ...passed This indicates that a system operator has manually omitted the corresponding zone Refer to Omitting Zones on page 16 for information on how to manually omit a zone s prior to setting the system...
Page 30: ...transmission has come from the control panel that has an ID number of 678 and that zone 2 is in alarm The example also displays that zone 3 has been manually omitted and the system is Set 30 Solution...
Page 31: ...vices connected to your alarm system used to detect intrusion and cause an alarm condition Some forms of detection devices include PIR Passive Infrared Smoke detectors photoelectric beams reed switche...
Page 32: ...r silent operation This means that when the zone programmed for silent operation has been violated during the Set period your alarm system will communicate with the monitoring station without sounding...
Page 33: ...ing or handling or the damage was not due to causes beyond the control of Detection Systems such as lightning excessive voltage mechanical shock or damage arising out of abuse alteration or improper a...
Page 34: ...34 Solution Ultima Operators Manual Operators Manual UK Detection Systems...
Page 35: ...es Installation Company Technicians Name Technicians Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes Solution Ultima Operators Manual 35 Detection Systems Oper...
Page 36: ...TAY Mode 1 Day Alarm Enabled Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 User Code Names Master Code Default 2580 User Code 1 Y User Code 9 User Code 2 User Code 10 User Code 3 User Code 1...
Page 37: ...ic Unsetting Time AM PM Output Descriptions Output 1 Output 3 Output 2 Output 4 Omitting Method Standard Omitting YES NO Code To Omit YES NO Communication Options ARC Reporting YES NO Domestic Reporti...
Page 38: ...it RF Device ID Numbers Zone Number Zone Number 1 RF Device 1 ID Number Place RF Device ID Sticker Here RF Device 9 ID Number 2 RF Device 2 ID Number RF Device 10 ID Number 3 RF Device 3 ID Number RF...
Page 39: ...ing 26 Acknowledging Domestic Calls 26 Disable 27 Programming Telephone Numbers 27 Duress Alarm 15 Dynamic Battery Testing 30 E E2 Fault 19 Entry Delay 30 Entry Guard Timer 11 12 Entry Time 30 Event M...
Page 40: ...Sensor Watch 19 RF Transmitter Operations 14 S Sealed 31 Sensor Watch 19 31 Silent Alarm 31 Specifications 32 STAY Indicator 8 STAY Mode 1 11 31 Entry Guard Timer 11 STAY Mode 2 12 31 Entry Guard Tim...
Page 41: ...A member of the Bosch Group...