Chapter 3 Element Function
|
ScrEdit Software User Manual
Revision Apr. 30th, 2007, 2007PDD23000002
3-21
3.4 Bar
Element
Fig. 3.4.1 Bar element options
Table 3.4.1 Property Description of Bar Element
Property Description of Normal Bar Element
HMI reads the value of the corresponding PLC specific address (register) and converts the value to normal
bar element and then displays it on the screen.
Read Address
The address can be internal memory or the controller address. (Please refer to Table
3.2.2 Property Description of General Buttons.)
Text / Text Size
Font / Text Color
The user can set the text, text size, font and text color that provided by
Windows®
to determine the text display on the element. (Please refer to Table 3.2.2 Property
Description of General Buttons.)
Border Color
It is used to set the border color of the normal bar element.
Foreground Color
Background Color
It is used to set the foreground and background color of the normal bar element. For
example, the foreground color of the following example bar element is green and its
background color is yellow.
Standard
Raised
Sunken
Style
Left
The display progressing direction is from right to the left.
Right
The display progressing direction is from left to the right.
Top
The display progressing direction is from bottom to the top.
Display Format
Botom
The display progressing direction is from top to the bottom.
Data
Length
There are 16bits Word and 32bits
Double Word two options.
There are following data format
provided:
Word/Double Word
Detail
Data
Format
1. BCD
2. Signed
BCD
3. Signed
Decimal
4. Unsigned
Decimal
5. Hex
Summary of Contents for AE80THTD