Chapter 3 Element Function
|
ScrEdit Software User Manual
Revision Apr. 30th, 2007, 2007PDD23000002
3-47
Property Description of Numeric Entry Element
Leading Zero
The following figures show the difference if the user selects the Leading Zero option.
(Please note that the integral digits are set to 4.)
(If YES is selected, the numeric value will show as this one.)
(If NO is selected, the numeric value will show as this one.)
Trigger
Trigger Mode
The user can use this setting to trigger the designated controller address to be ON
before or after writing the setting value. Please note that this function can only trigger
the controller address to be ON. If the controller address needs to be triggered again,
the user should set the address to be OFF manually.
Date Length
There are 16bits Word and 32bits Double Word two options.
There are following data format provided:
Word
Double Word
Data Format
1. BCD
2. Signed
BCD
3. Signed
Decimal
4. Unsigned
Decimal
5. Hex
6. Binary
1. BCD
2. Signed
BCD
3. Signed
Decimal
4. Unsigned
Decimal
5. Hex
6. Binary
7. Floating
Detail
Edit System
Keypad
When the input mode is Touch Popup, the user can define the
style of the keypad, including title, font, font size, font color and
keypad color. The position that the system keypad cannot display
will be placed in the center of the screen.
Summary of Contents for AE80THTD