System Event Message
Description/Meaning or Action
NVRAM not detected. Ensure card is seated properly.
Verify that the NVRAM card is seated properly in the DR
Series system appliance. Contact Dell Support for assistance
or intervention.
NVRAM capacitor is disconnected.
Contact Dell Support for assistance or intervention.
NVRAM capacitor has degraded.
Contact Dell Support for assistance or intervention.
NVRAM SSD is disconnected.
Contact Dell Support for assistance or intervention.
NVRAM has failed to backup or restore data during the
last boot.
Contact Dell Support for assistance or intervention.
NVRAM hardware failure.
Contact Dell Support for assistance or intervention.
Data volume is not present. Check that all drives are
inserted and powered up.
Contact Dell Support for assistance or intervention.
Filesystem server failed to start after multiple attempts. Contact Dell Support for assistance or intervention.
Filesystem server crashed multiple times. System is
now entering Maintenance mode.
Contact Dell Support for assistance or intervention.
Insufficient disk space. Filesystem switched to read-
only mode.
Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.
Unable to detect filesystem type on the Data Volume.
Contact Dell Support for assistance or intervention.
Unable to detect filesystem type on the Namespace
Volume.
Contact Dell Support for assistance or intervention.
Filesystem scan discovered inconsistencies.
Please check report and take the recommended action.
Contact Dell Support for assistance or intervention.
NVRAM does not match data volume.
If this is a newly replaced NVRAM device, use the CLI
maintenance --hardware --reinit_nvram command. For more
information, see the
Dell DR Series System Command Line
Reference Guide
.
Storage usage is approaching the DR Series system
capacity.
Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.
Replication resync cannot proceed because the
Namespace depth has reached its maximum.
Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.
Filesystem has reached the maximum allowable file(s)
and directories limit. New file and directory creation
will be denied until sufficient space exists.
Please clean up the filesystem. If issue persists, contact Dell
Support for assistance or intervention.
Filesystem is reaching the maximum allowable file(s)
and directories limit. New file and directory creation
will be denied after the limit has been reached.
Please clean up the filesystem. If issue persists, contact Dell
Support for assistance or intervention.
Replication has encountered an unexpected error.
Contact Dell Support for assistance or intervention.
156