2-10
Diagnostics and Troubleshooting Guide
Table 2-2. System Beep Codes
Code
Cause
Action
1-1-2 Microprocessor
register
failure
See Chapter 7, “Getting Help,” for instructions on obtaining technical
assistance.
1-1-3
NVRAM
Run the System Set Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.”
1-1-4
ROM BIOS checksum
failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-2-1
Programmable interval timer
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-2-2
DMA initialization failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-2-3
DMA page register read/
write failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
1-3
Video Memory Test failure
Run the Video Test Group in the Dell Diagnostics. See Chapter 4, “Run-
ning the Dell Diagnostics.”
1-3-1
through
2-4-4
SIMMs or DIMMs not being
properly identified or used
See “Troubleshooting System Memory” in Chapter 7.
3-1-1
Slave DMA register failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
3-1-2
Master DMA register failure
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
3-1-3
Master interrupt mask
register failure
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
3-1-4
Slave interrupt mask
register failure
Otherwise, see Chapter 7, “Getting Help,” for instructions on obtaining
technical assistance.
3-2-2
Interrupt vector loading
failure
See Chapter 7, “Getting Help,” for instructions on obtaining technical
assistance.
3-2-4
Keyboard Controller Test
failure
Run the Keyboard Test Group in the Dell Diagnostics. See Chapter 4,
“Running the Dell Diagnostics.” Otherwise, see Chapter 7, “Getting
Help,” for instructions on obtaining technical assistance.
3-3-1
NVRAM power loss
Run the System Set Test Group in the Dell Diagnostics, if possible. See
Chapter 4, “Running the Dell Diagnostics.”
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list that precedes the
Index.
Summary of Contents for OptiPlex HUB
Page 1: ... 1267 6 1 7528 6 227 1 8 ...
Page 2: ......
Page 3: ... 1267 6 1 7528 6 227 1 8 ...
Page 10: ...x ...
Page 18: ...xx DELL CONFIDENTIAL Preliminary 2 10 98 ...
Page 20: ...xxii DELL CONFIDENTIAL Preliminary 2 10 98 ...
Page 38: ...2 14 Diagnostics and Troubleshooting Guide ...
Page 42: ...3 4 Diagnostics and Troubleshooting Guide ...