iDRAC6 Enterprise Property Database Group and Object Definitions
435
2 = Auto Attach
Default
0
Description
This object is used to attach virtual devices to the system via the USB bus.
When the devices are attached the server will recognize valid USB mass
storage devices attached to the system. This is equivalent to attaching a local
USB CDROM/floppy drive to a USB port on the system. When the devices
are attached you then can connect to the virtual devices remotely using
iDRAC6 Web interface or the CLI. Setting this object to
0
will cause the
devices to detach from the USB bus.
NOTE:
You must restart your system to enable all changes.
cfgVirMediaBootOnce (Read/Write)
Legal Values
1 (Enabled)
0 (Disabled)
Default
0
Description
Enables or disables the virtual media boot-once feature of iDRAC6. If this
property is enabled when the host server is rebooted, this feature will attempt
to boot from the virtual media devices—if the appropriate media is installed
in the device.
cfgVirMediaKeyEnable (Read/Write)
Legal Values
1 (TRUE)
0 (FALSE)
Summary of Contents for IDRAC6
Page 38: ...38 iDRAC6 Enterprise Overview ...
Page 84: ...84 Configuring the Managed Server ...
Page 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Page 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Page 166: ...166 Configuring Smart Card Authentication ...
Page 222: ...222 Using GUI Console Redirection ...
Page 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Page 270: ...270 Using the RACADM Command Line Interface ...
Page 308: ...308 Using iDRAC6 Configuration Utility ...
Page 334: ...334 Recovering and Troubleshooting the Managed System ...
Page 382: ...382 RACADM Subcommand Overview ...
Page 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Page 462: ...462 Glossary ...
Page 472: ...472 Index ...