316
Recovering and Troubleshooting the Managed System
Checking the Server Status Screen for Error Messages
When a flashing amber LED is lit, and a particular server has an error,
the main Server Status Screen on the LCD will highlight the affected server
in orange. Use the LCD navigation buttons to highlight the affected server,
then click the center button. Error and warning messages will be displayed on the
second line. The following table lists all of the error messages and their severity.
Save As
Creates a compressed .zip file that contains all boot capture
images of the current sequence. The user must have
administrator privileges to perform this action.
Previous Screen
Takes you to previous screen, if any, in the replay console.
Play
Starts the screenplay from current screen in the replay console.
Pause
Pauses the screenplay on the current screen being displayed in
the replay console.
Stop
Stops the screenplay and loads the first screen of that boot
sequence.
Next Screen
Takes you to next screen, if any, in the replay console.
Prints the Boot Capture image that appears on the screen.
Refresh
Reloads the Boot Capture screen.
Table 20-8.
Server Status Screen
Severity
Message
Cause
Warning
System Board Ambient Temp:
Temperature sensor for System
Board, warning event
Server ambient temperature
crossed a warning threshold
Critical
System Board Ambient Temp:
Temperature sensor for System
Board, failure event
Server ambient temperature
crossed a failure threshold
Critical
System Board CMOS Battery:
Battery sensor for System Board,
failed was asserted
CMOS battery is not present or
has no voltage
Table 20-7.
Boot Capture Options
(continued)
Button/Option
Description
Summary of Contents for IDRAC6
Page 38: ...38 iDRAC6 Enterprise Overview ...
Page 84: ...84 Configuring the Managed Server ...
Page 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Page 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Page 166: ...166 Configuring Smart Card Authentication ...
Page 222: ...222 Using GUI Console Redirection ...
Page 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Page 270: ...270 Using the RACADM Command Line Interface ...
Page 308: ...308 Using iDRAC6 Configuration Utility ...
Page 334: ...334 Recovering and Troubleshooting the Managed System ...
Page 382: ...382 RACADM Subcommand Overview ...
Page 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Page 462: ...462 Glossary ...
Page 472: ...472 Index ...