356
RACADM Subcommand Overview
racadm getsel [-E] [-R] [-A] [-o] [-c
count
] [-s
count
] [-m]
Description
The
getsel -i
command displays the number of entries in the SEL.
The following
getsel
options (without the
-i
option) are used to read entries.
NOTE:
If no arguments are specified, the entire log is displayed.
Output
The default output display shows the record number, timestamp, severity, and
description.
For example:
Record:
1
Date/Time:
11/16/2005 22:40:43
Severity:
Ok
Description: System Board SEL: event log sensor for
System Board, log cleared was asserted
Supported Interfaces
•
Local RACADM
•
Remote RACADM
Table A-21.
getsel Subcommand Options
Option
Description
-A
Specifies output with no display headers or labels.
-c
Provides the maximum count of entries to be returned.
-o
Displays the output in a single line.
-s
Specifies the starting record used for the display.
-E
Places the 16 bytes of raw SEL at the end of each line of output as a
sequence of hex values.
-R
Only the raw data is printed.
-m
Displays one screen at a time and prompts the user to continue (similar to
the UNIX
more
command).
Summary of Contents for IDRAC6
Page 38: ...38 iDRAC6 Enterprise Overview ...
Page 84: ...84 Configuring the Managed Server ...
Page 120: ...120 Configuring iDRAC6 Enterprise Using the Web Interface ...
Page 160: ...160 Using iDRAC6 With Microsoft Active Directory ...
Page 166: ...166 Configuring Smart Card Authentication ...
Page 222: ...222 Using GUI Console Redirection ...
Page 228: ...228 Configuring the vFlash Media Card for Use With iDRAC6 ...
Page 270: ...270 Using the RACADM Command Line Interface ...
Page 308: ...308 Using iDRAC6 Configuration Utility ...
Page 334: ...334 Recovering and Troubleshooting the Managed System ...
Page 382: ...382 RACADM Subcommand Overview ...
Page 452: ...452 iDRAC6 Enterprise Property Database Group and Object Definitions ...
Page 462: ...462 Glossary ...
Page 472: ...472 Index ...