Table 34 VxFlex OS Alerts in SNMP, VxFlex OS GUI, REST, and ESRS (continued)
Alert Message in
VxFlex OS GUI
Alert Message in
REST
Alert
Message in
SNMP Trap
Alert Code
(for ESRS)
Severity
Recommended Action
The physical CPU
socket is not
enabled
SOCKET_DISABLED
Node.Cpu_Soc
ket.Disabled
SIO07.03.000
0001
3 (Error)
Enable the CPU socket in
the server BIOS.
Not all CPU cores
are enabled
SOCKET_NOT_ALL_CO
RES_ENABLED
Node.Cpu_Soc
ket.NOT_ALL_
CORES_ENABL
ED
SIO07.03.000
0002
3 (Error)
Change the physical CPU
core configuration in the
server BIOS.
CPU is not operating
at full speed
SOCKET_SPEED_IS_N
OT_MAX_SPEED
Node.Cpu_Soc
ket.SPEED_IS_
NOT_MAX_SP
EED
SIO07.03.000
0003
3 (Error)
Set the CPU clock speed in
the server's BIOS to its
maximum speed.
CPU temperature is
not within threshold
CPU_SOCKET_INVALID
_TEMPERATURE
Node.Cpu_Soc
ket.INVALID_T
EMPERATURE
SIO07.03.000
0004
5 (Critical) 3
(Error)
The server's CPU
temperature has exceeded
the configured threshold.
Make sure that the server is
properly cooled and that
the CPU and internal
chassis fans are active.
The CPU Voltage
Regulator's
temperature is
higher than the
configured threshold
CPU_SOCKET_INVALID
_VR_TEMPERATURE
Node.Cpu_Soc
ket.INVALID_V
R_TEMPERAT
URE
SIO07.03.000
0005
5 (Critical) 3
(Error)
Make sure that the server is
properly cooled and that
the CPU and internal
chassis fans are active.
The CPU Voltage
Regulator's voltage
is not within the
configured threshold
CPU_SOCKET_INVALID
_VR_VOLTAGE
Node.Cpu_Soc
ket.INVALID_V
R_VOLTAGE
SIO07.03.000
0006
5 (Critical) 3
(Error)
1. Verify that the power
supply is functioning
correctly. 2. Try to replace
a port in the Power
Distribution Unit, or supply
an external power source to
check it. 3. Replace the
power cable. 4. Replace the
Power Supply Unit module.
CPU has invalid
voltage state state
CPU_SOCKET_INVALID
_VOLTAGE
Node.Cpu_Soc
ket.Invalid_Volt
age
SIO07.03.000
0007
5 (Critical)
Check the chassis power
supply
RAM temperature is
not within threshold
RAM_INVALID_TEMPE
RATURE
Node.Ram.Inval
id_Temperature
SIO07.04.000
0001
5 (Critical) 3
(Error)
The temperature of one or
more Server RAM modules
exceeds the configured
threshold. Ensure that the
server and its environment
are properly cooled and
that all the chassis fans are
functional.
SNMP Trap Support
Dell EMC VxFlex Ready Node AMS User Guide
307
Summary of Contents for EMC VxFlex Ready Node
Page 1: ...Dell EMC VxFlex Ready Node Version 3 x AMS User Guide P N 302 005 733 REV 02 June 2019 ...
Page 10: ...Contents 10 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 12: ...Figures 12 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 14: ...Tables 14 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 18: ...Introduction 18 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 24: ...Introduction to VxFlex Ready Node 24 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 80: ...Architecture 80 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 110: ...VxFlex OS Performance Fine Tuning 110 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 130: ...Managing and Monitoring 130 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 156: ...Managing System Objects 156 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 182: ...Security Management 182 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 188: ...Monitoring the System using the VxFlex OS GUI 188 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 252: ...Reference 252 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 274: ...Common Tasks 274 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 292: ...System events 292 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 324: ...SNMP Trap Support 324 Dell EMC VxFlex Ready Node AMS User Guide ...
Page 348: ...DTK Hardware Update Bootable ISO 348 Dell EMC VxFlex Ready Node AMS User Guide ...