1 - 2
Chapter 1 Troubleshooting
Version 2 2008.03.31
7) The Multi Function Printer is not installed under direct sunlight.
8) The Multi Function Printer is installed in a well-ventilated place.
9) The Multi Function Printer is installed on a firm and stable surface.
10) The paper meets the specifications (standard paper is recommended).
11) The Multi Function Printer is handled properly.
12) The high frequency service items are replaced at the recommended print count intervals.
1.3 Cautions on Service Operations
1) Be sure to remove the power cord unless otherwise required.
While the Multi Function Printer is powered ON, never touch the conductive parts
unless otherwise required.
Never touch the conductive parts of the power switch and inlet of the LVPS,
because they are live even while the printer is powered off.
2) When checking some parts with covers removed and with the interlock, safety, and power switches
ON, disconnect the connectors (P/J411 and P/J412) on the ROS ASSY unless otherwise required.
When checking some parts with covers removed and with the interlock, safety, and
switches ON, laser beams may be irradiated from the ROS ASSY. For your safety,
be sure to disconnect the connectors (P/J411 and P/J 412) unless otherwise
required.
3) When checking some parts with the Front Cover removed and the Multi Function Printer powered
ON, be sure to disconnect the connector (P/J16) on the PWBA MCU unless otherwise required.
When checking some parts with the Front Cover removed and the printer powered
ON, be sure to remove the connector (P/J16) on the MCU. Otherwise, a high voltage
may be output from the HVPS.
When connecting the connector (P/J16) on the MCU according to the instructions
in the FIP, never touch the HVPS and high voltage parts.
4) When outputting a high voltage using the Diag Tool, etc., keep all the covers on unless otherwise
required.
When outputting a high voltage using the Diag Tool, etc., ensure that:
- The high voltage carrying parts must never be touched.
- The instructions in this manual must be followed.
5) When operating the drive unit using the Diag Tool, etc., keep all the covers on unless otherwise
required.
When operating the drive unit using the Diag Tool, etc., ensure that:
- The drive unit must never be touched.
- The instructions in this manual must be followed.
6) When touching hot parts, be careful not to get burnt.
7) While working, be sure to wear a wrist band or the like to dissipate static charges from your body.
Summary of Contents for 2135CN
Page 1: ...Dell 2135cn Service Manual 09 Oct 2009 ...
Page 13: ...viii Version 1 2008 02 01 4 6 2 Caution label for toner cartridges Mnt00006KA ...
Page 14: ...ix Version 1 2008 02 01 Wsb00007KA ...
Page 15: ...x Version 1 2008 02 01 4 6 3 Caution label for SSI and tray Mnt00008KA ...
Page 16: ...xi Version 1 2008 02 01 4 6 4 Caution label for ROS Mnt00009KA ...
Page 17: ...xii Version 1 2008 02 01 4 6 5 Caution label for transfer belt and PHD unit Mnt00010KA ...
Page 19: ...xiv Version 3 2008 06 13 Mnt00012KB ...
Page 197: ...1 169 Chapter 1 Troubleshooting Version 2 2008 03 31 Flows 95 Solid black ...
Page 217: ...1 189 Chapter 1 Troubleshooting Version 3 2008 06 13 Flows 103 Grey Background Mnt01115KA ...
Page 219: ...1 191 Chapter 1 Troubleshooting Version 2 2008 03 31 Flows 104 Skew Mnt01116KA ...
Page 222: ...1 194 Chapter 1 Troubleshooting Version 2 2008 03 31 Flows 105 Paper damage Mnt01117KA ...
Page 382: ...1 354 Chapter 1 Troubleshooting Version 1 2008 02 01 Wsb02025KA ...
Page 388: ...1 360 Chapter 1 Troubleshooting Version 1 2008 02 01 Chart Parallelism Perpendicularity ...
Page 480: ...2 21 Chapter 2 Operation of Diag Version 3 2008 06 13 0 12 0 3 4 0 1 004 0 12 524 3 6 7 ...
Page 763: ...Chapter 5 Parts List Chapter 5 Parts List CONTENTS Version 1 2008 02 01 ...
Page 787: ...5 24 Chapter 5 Parts List Version 3 2008 06 13 PL10 5 Frame With Scanner Assy Illustration ...
Page 795: ...5 32 Chapter 5 Parts List Version 3 2008 06 13 PL10 9 Scanner Assy 1 2 Illustration ...
Page 811: ...6 12 Chapter 6 Principle of Operation Fax Version 1 2008 02 01 Blank Page ...
Page 824: ...6 25 Chapter 6 Principle of Operation Scanner Version 1 2008 02 01 Blank Page ...