DC3000 USER INTERFACE
67
4
Field Name
Action/Definition
Use Belt
Click
Use Belt
to transfer the "found" or calculated dimensions to the
Dimensioning Area
fields. The values are highlighted in yellow until the
page has been updated.
Dimensioning
Area
NOTE
: All these values, except for the
X Shift
,
are automatically populated by the
Find
Belt/Use Belt
commands
Scanner
Height
This indicates the distance from the scanner to conveyor belt surface.
Left Ignore
This indicates the distance from the center of the scan line to the left edge of
the belt. Scan points beyond this distance will be ignored.
Right Ignore
This indicates the distance from the center of the scan line to the right edge
of the belt. Scan points beyond this distance will be ignored.