TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
62
3
Field Name
Action/Definition
Certification Mode
Select
On
or
Off
from the drop-down list. Turn certification mode
on for certified / Legal-for-Trade applications. Turning
certification mode on causes most of the input fields in the
Dimensioning
Settings,
Dimensioning
Calibration,
Configuration,
and
Tach/Trigger
windows to be disabled (see
below).
Length, Width
Resolution (d)
Select the dimensioning length/width resolution from the choices
provided in the drop-down list. (d) represents the smallest
interval between two consecutive values used in the dimension
calculations.
Height Resolution (d)
Select the dimensioning height resolution from the choices
provided in the drop-down list.(d) represents the smallest
interval between two consecutive values used in the dimension
calculations.
Package Size Options
Minimum Package Size:
Length (mm)/(inch)
Width (mm)/(inch)
Height (mm)/(inch)
Enter the minimum package size length, width, and height in
inches or millimeters as indicated. Any package below these
minimums will be designated as a NoDim. Minimum units must
be greater than the (d) value
(See above).
Maximum Package Size
Length (mm)/(inch)
Width (mm)/(inch)
Height (mm)/(inch)
Enter the maximum package size length, width, and height in
inches or millimeters as indicated.
Any package above these maximums will be designated as a
NoDim.
Discard Package Size
Length/Width (mm)/(inch)
Height (mm)/(inch)
Enter the minimum length/width and height below which a
dimension result will be ignored. This accounts for possible
anomalies on the belt surface.
3. When you have finished making changes, click
Update
to save or click
Reset
to
revert to the previously saved values.