TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
26
2
5. From the menu tree under
Modify Settings
, select
Configuration
. The
Configuration window
opens.
6. Confirm the following items:
Dimensioner Model should be
MULTI HEAD
Software revision should be
1.6(19)
or GREATER.
7. Enter a unique name for the dimensioner in the
Dimensioner Name
field. The master
DM3610 should be named
“HEAD1”
(this dimensioner will be mounted to the left
looking downstream), the next DM3610
“HEAD2,”
and etc.
8. Click
Update
.
9. From the menu tree under
Modify Settings
, select
Dimensioning | Settings
. The
Dimensioning | Settings
window opens.
10. Make sure
DIM-in-Head Enabled
is set to
Off,
and
Certification Mode
is set to
Off.
IMPORTANT:
You must turn Certification Mode back on after
calibration is completed if this is a Legal-for-Trade system
11. Click
Update
.