ELECTRICAL INSTALLATION
39
3
3.3 GENERAL
ELECTRICAL
INSTALLATION
GUIDELINES
AND
PRECAUTIONS
It is important that you follow these general precautions when installing, setting up, operating,
maintaining, troubleshooting or replacing any Datalogic products, parts or related equipment.
As you plan and install your two-head dimensioning system, be sure to keep the following
guidelines in mind:
Determine the dimensioners are in the proper locations according to your application
drawings.
Leave adequate clearances (approximately 300 mm [12 inches]) around the
dimensioners and DC3000 Dimensioning Controller for wiring.
Route wires carefully to reduce or minimize electrical noise.
When power and communication wiring must cross, make their intersection
perpendicular. Avoid running power and data wiring parallel to each other. If possible,
maintain one of the following separations between the power and data wiring:
o
300 mm [12 inch] gap
o
use steel conduit and 25 mm [1 inch] gap
o
6.5 mm [0.25 inch] of aluminum.
IMPORTANT:
When planning your installation wiring, remember all power
connections must be quick-disconnect. For
PERMANENTLY CONNECTED
EQUIPMENT
a readily accessible disconnect device must be incorporated
in the building installation wiring. For
PLUGGABLE EQUIPMENT
the
socket-outlet must be installed near the equipment and must be easily
accessible.
WARNING:
To assure no ESD damage will occur, be sure to observe the
precautions outlined in the Introduction to this manual.
IMPORTANT:
Ground the mounting structure to safety ground (protective
earth ground (PE)). See wiring recommendations for safety ground.