4. Adjust the UMB so that the installation mark is at the center slot of the UMB
Mounting Disk, and then secure the mounting disk and bracket with the pitch angle
adjustment nuts.
4.
Figure 25: Aligning the UMB with the installation mark
NOTE:
DO NOT
over-tighten hardware that holds the UMB in-place.
5. Using a digital level or other angle finding device, adjust the degree of pitch angle of
each UMB based on the application drawing for your system. The laser should angle
in toward the conveyor. The angle may need to be adjusted based on your application
specifications and during the calibration process.
Figure 26: Adjusting the pitch angle
6. Slightly loosen the nuts on the UMB Mounting Disk on the UMB to adjust the pitch
angle.
NOTE:
Take care to only loosen the nuts and not the two set screws that
anchor the UMB to the mounting structure