DIMENSIONING SETUP AND CALIBRATION
111
5
5.3 ELECTRONICALLY ALIGNING THE SYSTEM LASERS
5.3.1 Adjusting the Field of View and Angle Offset for Each
Dimensioner
(DM3610 User Interface)
The field of view (FOV) and angle offset of
each
DM3610 dimensioner must be adjusted
manually using the
DM3610 User Interface
to cover its portion of the dimensioning area over
the conveyor. Perform the following adjustments for
each
DM3610:
1.
Configure your laptop PC’s IP Address to be in the same network as the DM3610’s IP
Address (example: 192.168.3.1)
See section 4.1.2.
2. Connect your laptop computer to the DM3610 HEAD1 HOST port using either the CAB-
ETH-M0x M12-IP67 ETHERNET CABLE or CBL-1534-0.2 ADAPT.CABLE ETH M12-TO-
RJ45F.
3. Open a browser on the laptop computer, and type in the default IP address for the
DM3610 to which your PC is attached (HEAD1 - 192.168.3.101, HEAD2 -
192.168.3.102). The
DM3610 User Interface
opens in the browser window.
NOTE:
Details on using the DM3610 User Interface are
available in the
DM3610 Dimensioner Reference Manual
,
Chapter 4
.
4. Open a browser tab for both
HEAD1
(192.168.3.101) and
HEAD2
(192.168.3.102), and
log on to their user interfaces.
5. From the menu tree
Modify Settings
, navigate to
Dimensioning | Calibration
. The
Calibration window opens.
Summary of Contents for DM3610