TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
138
7
7.1 DC3000 DIMENSIONING CONTROLLER ERROR CODES AND
RESOLUTIONS
NOTE:
The following error codes pertain to a DC3000 Dimensioning
Controller using certified dimensioning. If the DC3000 is providing volume
information only, some of these codes do not apply.
For DM3610 HEAD errors, see the
DM3610 Dimensioner Reference
Manual.
BOX_NODIM_UNKNOWN,
// Set if unknown error caused the NoDim
BOX_TOL_FAIL_LENGTH,
// Set if box tolerance check failed - length
BOX_TOL_FAIL_WIDTH,
// Set if box tolerance check failed - width
BOX_TOL_FAIL_HEIGHT,
// Set if box tolerance check failed - height
BOX_WRITE_ALIBI_FAIL,
// Set if attempt to write box results to Alibi
store failed
BOX_STACKED,
// Set if box is stacked with another box
BOX_LOW_FILL_RATE,
// Set if the bounding box fill rate is below our
threshold
BOX_TILTED_TOP,
// Set if the bounding box top is tilted
BOX_LOWNEARTILTEDTOP,
// Set if low box near tilted top box (possibly
shingled)
BOX_BADBAGZ,
// Set if ratio of good points used to calc bagZ
and points in the initial histo peak is < some
threshold
BOX_BADBELTPTS,
// Set if there are significant belt points
underneath the top surface ("3D" bbox workaround)
MAX_NODIM_REASONS