MAINTENANCE
135
6
6.2.5 Tighten Mounting Hardware
1. Check all DM3610 Dimensioner, CBX100 connection box, and power supply
mounting hardware. Tighten as necessary. Do not over-tighten. Be sure not to
disturb the equipment’s alignment as it relates to the product transport.
2. Check the mounting hardware of the Photoelectric Sensor (if this option is
being used). Tighten as necessary. Do not over-tighten.
3. Check the mounting hardware of the tachometer (if this option is being used).
Tighten as necessary. Do not over-tighten.
6.2.6 Checking Dimensioning System Connections
Wiring connections to the DM3610 are made to the connector panel and CBX100.
(See chapter 3, Electrical Installation.)
1. Check all wiring connections to the connector panel.
Tighten any loose connections as necessary. Do not over-tighten.
2. Check all wiring connections to the CBX100.
Tighten any loose connections as necessary. Do not over-tighten.
3. Check all cabling/conduit for signs of wear/damage.
Repair/replace any damaged cable connections as necessary.
6.2.7 Verify System Operation
If after performing maintenance, the dimensioning system continues to perform below the
normal operations experienced with the system under normal daily conditions, contact
Datalogic through the
Technical Support
6.2.8 Verify Photoelectric Sensor Operation
1. Block the Photoelectric Sensor emitter beam to confirm it is aligned properly
with the reflector.
2. Verify that the TRIGGER LED on DM3610 is green when photoelectric sensor
beam is blocked.
3.
If the photoelectric sensor’s LED does not change status, adjust the
photoelectric sensor so that it is properly aligned with the reflector.
4. If the TRIGGER LED on the DM3610 is not green when the photoelectric
sensor’s beam is blocked, check the cabling between the photoelectric sensor
and CBX100 for damage.