Introduction ■ Room Consideration
- 30 -
Data I/O ■ 096-0465-001C
T
HE INTENDED AREA FOR INSTALLATION MUST
:
• allow at least one meter (39 inches) of clearance on all sides of the
machine for opening access panels as well as repairing and
replacing subassemblies,
• provide a solid foundation (for example, a concrete floor). The
machine contains a fast-moving gantry with much mass. The area
for it must be stable, solid, and mostly level prior to installation. If
this is not achievable, consider installing the system at another
location.
The table below lists recommended, minimum envelope size
determined by the 1 meter access space required on each side:
M
INIMUM
P
HYSICAL
E
NVELOPE
Note:
The numbers below
do not
include ventilation requirements
discussed in the previous heading Ventilation.
Machine
Configuration
Width x Depth
(X-axis x Y-axis)
Width x Depth
+ 1 m all sides
for access
PSV5000 Only
1.5 m x 0.87 m
3.5 m x 2.87m
P Laser
1.3 m x 0.87 m
3.2 m x 2.87m
P Tray Feeder
2.1 m x 0.87 m
4.1 m x 2.87 m
P Tape Out
Module with Large reel
2.2 m x 0.87 m
4.2 m x 2.87 m
P Tray Feeder
+ Tape Out Module with
Large reel
2.9 m x 0.87m
4.9 m x2 .87m
For example, a PSV5000 System with a Tray Feeder requires a
minimum physical area of 4.1 meters wide x 2.87 meters deep for
easy access.
Summary of Contents for PSV5000
Page 12: ......
Page 36: ......
Page 160: ......
Page 161: ...Electrical Schematics for PSV5000 and Equipment ...
Page 162: ......
Page 163: ......
Page 164: ......
Page 165: ......
Page 166: ......
Page 167: ......
Page 168: ......
Page 169: ......
Page 170: ......
Page 171: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ...PROGRAMMABLE MEDIA EXPERTS ...