4.10 Parameters: 9-** PROFIdrive
9-00 Setpoint
Range:
Function:
0
*
[0 -
65535 ]
This parameter receives cyclic reference from a
master class 2. If the control priority is set to
master class 2, the reference for the frequency
converter is taken from this parameter, whereas
the cyclic reference is ignored.
9-07 Actual Value
Range:
Function:
0
*
[0 - 65535 ] This parameter delivers the MAV for a master
class 2. The parameter is valid if the control
priority is set to master class 2.
9-15 PCD Write Configuration
Option:
Function:
Select the parameters to be
assigned to PCD 3–10 of the
telegrams. The number of
available PCDs depends on
the telegram type. Values in
PCD 3–10 are written to the
selected parameters as data.
For standard PROFIBUS
telegrams, see
parameter 9-22 Telegram
Selection
[0]
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp Up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp Up Time
[352]
Ramp 2 Ramp Down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[412]
Motor Speed Low Limit
[Hz]
[414]
Motor Speed High Limit
[Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator
Mode
[553]
Term. 29 High Ref./Feedb.
Value
[558]
Term. 33 High Ref./Feedb.
Value
[590]
Digital & Relay Bus Control
[593]
Pulse Out 27 Bus Control
[615]
Terminal 53 High Ref./
Feedb. Value
9-15 PCD Write Configuration
Option:
Function:
[625]
Terminal 54 High Ref./
Feedb. Value
[696]
Terminal 42 Output Bus
Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[3401] PCD 1 Write For
Application
[3402] PCD 2 Write For
Application
[3403] PCD 3 Write For
Application
[3404] PCD 4 Write For
Application
[3405] PCD 5 Write For
Application
[3406] PCD 6 Write For
Application
[3407] PCD 7 Write For
Application
[3408] PCD 8 Write For
Application
[3409] PCD 9 Write For
Application
[3410] PCD 10 Write For
Application
9-16 PCD Read Configuration
Option:
Function:
Select the parameters to be
assigned to PCD 3–10 of
the telegrams. The number
of available PCDs depends
on the telegram type.
Values in PCD 3–10 contain
the actual data values of
the selected parameters.
[0]
[1500] Operating hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference [%]
[1603] Status Word
[1605] Main Actual Value [%]
[1609] Custom Readout
[1610] Power [kW]
[1611] Power [hp]
[1612] Motor Voltage
Parameter Descriptions
Programming Guide
MG07C102