37-14 Pos. Ctrl. Source
Selects the control source for positioning control.
Option:
Function:
[0]
*
DI
[1]
FieldBus
37-15 Pos. Direction Block
Use this parameter to configure whether to block a direction,
and the direction to be blocked.
Option:
Function:
[0]
*
No Blocking
[1]
Block Reverse
[2]
Block Forward
37-16 Pos. Power Recovery
Configures whether to enable the power recovery function.
Option:
Function:
[0]
Disable
[1]
*
Enable
37-17 Pos. Ctrl Fault Behaviour
This parameter determines the behavior of the frequency
converter after a fault is detected.
Option:
Function:
[0]
*
Ramp Down&Brake
[1]
Brake Directly
37-18 Pos. Ctrl Fault Reason
READ-ONLY PARAMETER: The current fault reason of the alarm.
POSITION CTRL FAULT
is displayed in this parameter.
Option:
Function:
[0]
*
No Fault
[1]
Homing Needed
[2]
Pos. HW Limit
[3]
Neg. HW Limit
[4]
Pos. SW Limit
[5]
Neg. SW Limit
[7]
Brake Wear Limit
[8]
Quick Stop
[9]
PID Error Too Big
[12]
Rev. Operation
[13]
Fwd. Operation
[20]
Can not find home position
37-19 Pos. New Index
The currently latched index number.
Range:
Function:
0
*
[0 - 255 ]