![background image](http://html.mh-extra.com/html/danfoss/vlt-midi-drive-fc-280/vlt-midi-drive-fc-280_programming-manual_506511134.webp)
5.2.24 37-** Application Settings
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
37-0* ApplicationMode
37-00 Application Mode
[0] Drive mode
1 set-up
FALSE
-
Uint8
37-1* Position Control
37-01 Pos. Feedback Source
[0] 24V Encoder
1 set-up
FALSE
-
uint8
37-02 Pos. Target
0 N/A
1 set-up
FALSE
0
Int32
37-03 Pos. Type
[0] Absolute
1 set-up
FALSE
-
uint8
37-04 Pos. Velocity
100 RPM
1 set-up
FALSE
67
uint16
37-05 Pos. Ramp Up Time
5000 ms
1 set-up
FALSE
-3
uint32
37-06 Pos. Ramp Down Time
5000 ms
1 set-up
FALSE
-3
uint32
37-07 Pos. Auto Brake Ctrl
[1] Enable
1 set-up
TRUE
-
uint8
37-08 Pos. Hold Delay
0 ms
1 set-up
TRUE
-3
uint32
37-09 Pos. Coast Delay
200 ms
1 set-up
TRUE
-3
uint16
37-10 Pos. Brake Delay
200 ms
1 set-up
TRUE
-3
uint16
37-11 Pos. Brake Wear Limit
0 N/A
1 set-up
TRUE
0
uint32
37-12 Pos. PID Anti Windup
[1] Enable
1 set-up
TRUE
-
uint8
37-13 Pos. PID Output Clamp
1000 N/A
1 set-up
TRUE
0
uint16
37-14 Pos. Ctrl. Source
[0] DI
1 set-up
TRUE
-
uint8
37-15 Pos. Direction Block
[0] No Blocking
1 set-up
TRUE
-
uint8
37-17 Pos. Ctrl Fault Behaviour
[0] Ramp
Down&Brake
1 set-up
FALSE
-
uint8
37-18 Pos. Ctrl Fault Reason
[0] No Fault
1 set-up
TRUE
-
uint8
37-19 Pos. New Index
0 N/A
1 set-up
TRUE
0
uint8
Parameter Lists
VLT
®
Midi Drive FC 280
132
Danfoss A/S © 12/2015 All rights reserved.
MG07C102
5