Key
Function
9
[Back]
For moving to the previous step or layer
in the navigation structure.
10 Arrows [
▲
] [
▼
]
For switching between parameter groups,
parameters, and within parameters, or
increasing/decreasing parameter values.
Arrows can also be used for setting local
reference.
11 [OK]
Press to access parameter groups or to
enable a selection.
12 [
►
]
Press to move from left to right within
the parameter value to change each digit
individually.
Table 3.3 Legend to
, Navigation Keys
D. Operation keys and indicator lights (LEDs)
Key
Function
13 Hand On
Starts the frequency converter in local control.
•
An external stop signal by control input or
serial communication overrides the local
hand on.
14 Off/Reset
Stops the motor but does not remove power
to the frequency converter or resets the
frequency converter manually after a fault has
been cleared.
15 Auto On
Puts the system in remote operational mode.
•
Responds to an external start command by
control terminals or serial communication.
Table 3.4 Legend to
, Section D
WARNING
ELECTRICAL HAZARD
Even after pressing the [Off/Reset] key, voltage is present
at the terminals of the frequency converter. Pressing the
[Off/Reset] key does not disconnect the frequency
converter from mains. Touching live parts can result in
death or serious injury.
•
Do not touch any live parts.
3.1.2 The Right-key Function on NLCP
Press [
►
] to edit any of the 4 digits on the display
individually. When pressing [
►
] once, the cursor moves to
the first digit, and the digit starts flashing as shown in
. Press the [
▲
] [
▼
] to change the value.
Pressing [
►
] does not change the value of the digits, or
move the decimal point.
130BC440.10
Setup 1
Setup 1
Setup 1
Setup 1
Setup 1
Illustration 3.3 Right-key Function
[
►
] can also be used for moving between parameter
groups. When in Main Menu, press [
►
] to move to the first
parameter in the next parameter group (for example, move
from
parameter 0-03 Regional Settings
[0] International
to
parameter 1-00 Configuration Mode
[0] Open loop
).
NOTICE
During start-up, the NLCP shows the message
LCP ON
.
When this message is no longer shown, the frequency
converter is ready for operation. Adding or removing
options can extend the duration of start-up.