5.2.4 3-** Reference/Ramps
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
3-0* Reference Limits
3-00
Reference Range
[0] Min - Max
All set-ups
TRUE
-
Uint8
3-01
Reference/Feedback Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-02
Minimum Reference
0 ReferenceFeed-
backUnit
All set-ups
TRUE
-3
Int32
3-03
Maximum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-04
Reference Function
[0] Sum
All set-ups
TRUE
-
Uint8
3-1* References
3-10
Preset Reference
0 %
All set-ups
TRUE
-2
Int16
3-11
Jog Speed [Hz]
5 Hz
All set-ups
TRUE
-1
Uint16
3-12
Catch up/slow Down Value
0 %
All set-ups
TRUE
-2
Int16
3-14
Preset Relative Reference
0 %
All set-ups
TRUE
-2
Int16
3-15
Reference 1 Source
[1] Analog Input 53
All set-ups
TRUE
-
Uint8
3-16
Reference 2 Source
[0] No function
All set-ups
TRUE
-
Uint8
3-17
Reference 3 Source
[11] Local bus
reference
All set-ups
TRUE
-
Uint8
3-18
Relative Scaling Reference Resource
[0] No function
All set-ups
TRUE
-
Uint8
3-4* Ramp 1
3-40
Ramp 1 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-41
Ramp 1 Ramp Up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-42
Ramp 1 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-5* Ramp 2
3-50
Ramp 2 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-51
Ramp 2 Ramp Up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-52
Ramp 2 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-6* Ramp 3
3-60
Ramp 3 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-61
Ramp 3 Ramp up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-62
Ramp 3 Ramp down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-7* Ramp 4
3-70
Ramp 4 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-71
Ramp 4 Ramp up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-72
Ramp 4 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-8* Other Ramps
3-80
Jog Ramp Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-81
Quick Stop Ramp Time
ExpressionLimit
1 set-up
TRUE
-2
Uint32
3-9* Digital Pot.Meter
3-90
Step Size
0.10 %
All set-ups
TRUE
-2
Uint16
3-92
Power Restore
[0] Off
All set-ups
TRUE
-
Uint8
3-93
Maximum Limit
100 %
All set-ups
TRUE
0
Int16
3-94
Minimum Limit
-100 %
All set-ups
TRUE
0
Int16
3-95
Ramp Delay
1000 ms
All set-ups
TRUE
-3
uint32
3-96
Maximum Limit Switch Reference
25 %
All set-ups
TRUE
0
Int16
Parameter Lists
Programming Guide
MG07C102